logo
salesjkt@flotech.co.id

iSOLV EFS803B Battery Powered Electromagnetic Flowmeter


iSOLV electromagnetic flowmeter can be used for precise flow measurement of all electrically conductive liquids - sludges, slurries, sewage, milk, water. The only pre-requisite being that the minimum conductivity of the medium is greater than 5µS/cm. Temperature, viscosity, density has no influence on the measurement.

iSOLV electromagnetic flowmeter can be used for precise flow measurement of all electrically conductive liquids - sludges, slurries, sewage, milk, water. The only pre-requisite being that the minimum conductivity of the medium is greater than 5µS/cm. Temperature, viscosity, density has no influence on the measurement.

The measuring principle of the electromagnetic flowmeter (Magmeter) is based upon the Faraday’s Law of electromagnetic induction; whereby a voltage is induced by an electrical conductor passing through a magnetic field.
The following equation is applicable to the induced voltage:

U = kBVD

where :
U Induced voltage
k Instrument constant
B Magnetic field strength
V Velocity of the conductor
D Conductor width

In electromagnetic flowmeter, the medium acts as the electrical conductor when flowing through the meter tube, the induced voltage is proportional to the average flow velocity (the faster the flow rate, the higher the voltage). The induced voltage is picked up by a pair of electrodes (mounted in the meter tube) and transmitted to a flow transmitter to produce various standardized output signals.
Using the pipe cross-sectional area, the flow volume is calculated by the transmitter.

Application reference:


ENQUIRY
Request Price, Order and Brochure click here.
Features

• Up to 15 years of battery life
• Internal Data logger
• GSM Data Transmitting
• Conformed to OIML-R49
• Maintenance free operation
Application

• iSOLV electromagnetic flowmeter can be used for precise flow measurement of all  electrically conductive liquids, sludge, slurries, sewage, milk, water. The only pre-requisite
   being that the minimum conductivity of the medium is greater than 5 microsiemens/cm. temperature, viscosity, density has no influence on the measurement.
• With isolated inert linings and electrodes, flow measurement of very corrosive liquids (eg: acids, accaustics and corrosive chemicals) is not an issue.
• iSOLV electromagnetic flowmeter has many applications across many industries enviroment (pulp & Paper, water/wastewater, food and beverage, chemical, pharmaceutical,
   HVAC.
Specifications
• Accuracy : 0.5%
• Repeatability : +/- 0.1%
• Full scale range setting : 0.3 m/s
• Ambient temperature : -40° C to 65° C
• Compliant with : OIML R49

Overall features
• Size : DN25 - DN2000
• Fluid conductivity : >5 microsiemens/cm
• Humidity range : 0 + 100% (IP67)
• Ambient temperature :
 `-20....+65° C Alumunium housing
 `-10.... +50° C Reiforced Nylon
• LCD Display :
 `Graphic display 128x64 pixels back light, 3 programming keys
 `Communication and Data logger (optional)
• Communication : GPRS, 3G, 4G on request
• Data Logger MicroSD Memory Card 4...32 GBytes

Flowhead - Standard Features
• Body material : Carbon steel paited (SS304 or 316 ad optional)
• Nominal pressure : 1600 kPa (4000 kPa up to DN50), higher pressure on request
• Process connection : Flanges std - UNI PN 16
• Flanges material : Carbon steel (Std), (SS304 or 316 on request)
• Lining material :
 `Polipropilene (max PN 16)
 `Ebonite
 `PTFE (max PN 40)
 `Rilsan (max PN 16)
• Gasket material : FPM (Only for lining in Polypropylene)
• Liquid temperature :
 `0 - 70° C with Rilsan lining
 `0 - 60° C with PP lining
 `-5 - 80° C with ebonite lining
 `-20 - 100° C eith PTFE lining in compact version
• Vacuum resistance : 20 Kpa (absolute) at 100° C (60/80° C for PP/Ebonite)
• Electrodes material :
 `Acciaio inox AISI 316
 `Hastelloy
 `Platinum
 `Titanium
 `Tantalum

Converter-Standard Features
• Housing materials :
 `Painted alumunium die casting
 `Nylon reinforced with 15% of fiber glass
• Protection rate : IP67
• Cable gland : N° 5 cable gland PG 11
• Full scale value : 0,4....10 m/s
• Programming plug in : USB port for the connection to PC (USB cable type A/USB Mini B is required for the programmation)
FLOTECH CONTROLS INDONESIA
Jl. Boulevard Artha Gading - Artha Gading Niaga
Blok F/7, Kelapa Gading - Jakarta 14240 Indonesia
Telp: +62 21 45850778 / Fax: +62 21 45850779
Copyright © 2017 - PT Flotech Controls Indonesia || All Rights Reserved
Mobile Site